Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13641518

- Product Categories
- Friendly Links
Information Name: | Supply (Shenyang) Germany pine battery SB12V80AH battery power system |
Published: | 2015-01-15 |
Validity: | 365 |
Specifications: | SB12V80AH |
Quantity: | 600.00 |
Price Description: | |
Detailed Product Description: | (Shenyang) Germany pine battery SB12V80AH pine batteries battery power system maintenance and repair :( Shenyang) Germany pine battery SB12V80AH pine batteries battery power system using the UPS system in the process, people often one-sided that the battery is maintenance-free without adding attention. However, our data show that the proportion due to battery failure caused by a host failure or UPS is not working properly is about 1/3. Thus, strengthening the proper use and maintenance of the UPS battery to extend battery life and reduce the failure rate of UPS systems, with more and more important. In addition to the optional battery than regular brands, the following aspects should be the proper use and maintenance of the battery: 1. To maintain the proper ambient temperature. Important factors that affect battery life is the ambient temperature, ambient temperature is usually the best battery manufacturers requirement is between 20 ℃ ~ 25 ℃. Although the temperature rise of the battery discharge capacity has increased, but the cost is greatly reduced battery life. According to tests measuring the ambient temperature once more than 25 ℃, every increase of 10 ℃, the battery life would be shortened by half. UPS batteries currently used are generally VRLA batteries, universal design life of five years, which can be achieved in the battery manufacturer demanding environments. Less than the required environmental requirements, there is a great difference in the length of its life. In addition, the increase in ambient temperature can cause the battery internal chemical activity increased, resulting in a lot of heat, in turn prompting the ambient temperature rises, this vicious cycle will accelerate shorten battery life. 2. Regularly charge and discharge. UPS power supply system float voltage and discharge voltage at the factory have been commissioning rating, while the size of the discharge increases as the load is increased, the use should be reasonable to adjust the load, such as controlling computers and other electronic equipment The use of several. Under normal circumstances, the load should not exceed 60% UPS rated load. Within this range, the battery does not appear excessive discharge. UPS is connected to the mains due to long-term, high-quality power supply, power outages are rare use of the environment, the battery will be long-term in a floating charge state, a long time will cause the battery to chemical energy and electrical energy into each activity decreased, accelerated aging shorten life. Thus, generally every 2 to 3 months to be completely discharged once, discharge time can be determined based on the battery capacity and load size. After a full load discharge is completed, according to the provisions of more than 8 hours to recharge. |
Admin>>>
You are the 7403 visitor
Copyright © GuangDong ICP No. 10089450, ASUS Beijing Bo Yuan Electronics Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 7403 visitor
Copyright © GuangDong ICP No. 10089450, ASUS Beijing Bo Yuan Electronics Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility